Dynamic Analysis of Multi-Storey Building for Minimization of Lateral Displacement due to Earthquake Using Shear Wall

Main Article Content

Kushalkumar Yadav, Tarunbir Singh

Abstract

Shear wall are one of the most commonly used in Multi-Storey buildings for resisting the lateral load. In this paper, the multistorey building is modeled and analyzed by STAAD-Pro Software. Building with shear wall is analyzed using STAAD-Pro software and the comparison is done withmodelwithout shear wall. The main focus on the studies of seismic behavior of shear wall in multi-storey building and it will be discussed in detail. The calculation is done by using the IS Code IS 1893:2002, criteria for earthquake resistant design of structures part 1 general provisions and buildings. And the use of IS456:2000, and IS875:1987also have been done in this paper.  The results of Displacements and storey drift havebeen computed in both the cases with and without shear wall in STAAD-Pro by using Response Spectrum Method and areobserved as, buildings, employing shear walls at the exterior corners leads to an impressive 77.28% reduction in displacement, while placing them in the middle of the exterior wall achieves a slightly higher reduction of 77.63%. This emphasizes the effectiveness of shear walls in both configurations, with a marginal advantage for the latter.

Article Details

Section
Articles